ADsorption Chillers superior to absorption chillers in waste heat applications used in Green Building Systems.

New, ADsorption Chiller uses a very Green Refrigerant (WATER) to provide a source of safe efficient energy conservation by utilizing waste heat to drive an Adsorption chiller to replace toxic and very maintenance intensive LiBr absorption chiller.
Waste heat from cogeneration systems (diesel engine, gas engine, gas turbine, or fuel cell) achieves tri-generation. Using solar heat and the waste heat from various processes including: food (poultry, dairy products, juice, and breweries), chemical, plastic, rubber, paper and cement can enhance the heat balance of the process. Additionally, steam boilers, used year round, in hospitals and hotels can utilize their excess heat to cool their facilities.
Components
The Adsorption Chiller contains only water as a refrigerant and a proprietary, permanent silica gel (lasts 30 years) as an adsorbent. The evaporator section cools the chilled water by the refrigerant (water) being evaporated by adsorption of the silica gel in one of two adsorbent chambers. It can produce chilled water temperatures of less than 38F with hot water temperatures ranging from 194 to as low as 122F. The hot water regenerates the silica gel in the second of the two adsorbent chambers. The water vapor released from the silica gel by the hot water will be condensed in the condenser section, which is cooled by cooling water, such as, from a cooling tower.

The Adsorption Chiller has very low operational costs. The chiller’s electrical load of just 0.4KW, for the 180-ton model, is for the controls and two small pumps. One is a vacuum pump for non-condensables and the other is a refrigerant liquid (water) pump that runs only while unloading. Other operational costs such as maintenance are also very low.

  • Water used as refrigerant, no freon, no Li-Br, no ammonia means : No hazardous leaks, no corrosion, no chemical testing, no replacement.
  • No compressor means: No alignment, no high voltage, no high pressure, no overhaul, no oil change, no surging, no vibration or noise.
  • Stable chilled water out-put driven by a wide range (194 to 122 F) of hot water.
  • Capacity out-put remains stable as in-put fluctuates. No back up burner required.
  • Simple and short start up / shut down time
  • 38F of chilled water is in the standard specification.
Constant operation - 24 hours / 7 days a week.

How it works?
Typical Installation & Plaot
 ADsorption Vs ABsorption Chillers???
AdsorptionVsAbsorption
Current AD CHillers Capacity Range.
Document
AD Chiller Performance Table
Image: 

Dealers and Distributors


Document
Contact List
Sign Guestbook
View Guestbook
Please sign in to send more info.
HIJC USA, INC.
P.O. BOX 820307, Houston, Texas, 77282-0307, US 

hijcusa@greenchiller.biz

Privacy Policy/Terms of Service
Copyright (C) 2001 HIJC USA INC.